Archives
April 2001 Issue Broadband: Two-Way Success Secrets Revealed By
Pssst!
Ive got something to tell you. Its not widely known, so we need to be discreet about this. Wanna know the secret to making your reverse path work well?
Gotcha. There is no secret weapon to successful two-way operation. For the most part, its nothing more than back-to-basics stuff youve known for years, such as proper network alignment, signal leakage management, compliance with relevant technical specifications and effective maintenance and troubleshooting practices.
Ive seen too many attempts to "plug-n-play" when it comes to two-way operation. You knowplug in the reverse amp modules, equalizers and attenuators, and assume the job is done. In some cases, this task is accompanied by turning the reverse amp gain controls to maximum. Thats not the way to make two-way work.
Network alignment
Assuming your network was designed with unity gain in mind (see "Seek Balance in All Things: A Look at Unity Gain in the Upstream Coax Plant," June 2000 Communications Technology), and youve plugged in the reverse amp modules, you should start with downstream and upstream network alignment.
You must properly align the downstream and upstreamincluding fiber linksif you want the reverse path to work well. Its not possible to characterize the extent of upstream ingress, common path distortion (CPD) and other potential impairments without first aligning the network. From a big picture perspective, you cant tell how good or bad the reverse is if its not correctly aligned. For instance, if overall levels are too low, a spectrum analyzer display in the headend might indicate very low levels of ingress or other problems. Conversely, if overall levels are too high, the reverse spectrum might look like its absolutely unusable. Of course, if the reverse is running wide open, it probably will be unusable.
Several years ago, I assisted a cable operator with its corporate headquarters engineering lab. The lab included a simulated cable network, complete with a two-way fiber link, an eight-amplifier cascade and a section of tapped feeder. I was teaching the operator how to align the network for two-way operation, and we started with downstream alignment. As we progressed through the amp cascade, we noticed what appeared to be common path distortion in the reverse spectrum. The problem eventually was traced to what we all believed was a defective diplex filter in one of the amplifiers because it appeared that downstream signals from that amp were overdriving the upstream module.
Well, sort of.
The real problem was improper alignment of the downstream amplifier. We discovered that the multi-output amplifier had individual internal level adjustments (plug-in pads) for each output port. The amps main output had been adjusted correctly, but the other two were cranked to the max. The downstream was indeed overdriving the reverse amp. When all of the amps downstream outputs were correctly adjusted, the upstream worked just fine.
I cant overemphasize the importance of properly aligning the network. Furthermore, Ill preach until the cows come home that alignment must be done using broadband sweep equipment. Some argue that modern hybrid fiber/coax (HFC) networks with short amplifier cascades after the node dont need to be swept. Ill never buy that argument. While its true that amplifier frequency response signature built-up is less of a problem in short cascades, sweep alignment still is necessary to see whats going on across the entire spectrum.
Broadband sweep will identify frequency response roll-off problems that arent evident with simple balance alignment techniques. As well, sweeping will identify defective or missing end-of-line terminations, water damage, response suckouts, over- or under-equalization and other problems that are difficult or impossible to see without sweeping. One word of caution: Make sure you program sweep guard bands around the downstream and upstream digitally modulated carriers. I cant tell you how many times Ive seen degraded bit error rate (BER) performance that was caused by the sweep transmitter sweeping right through the digitally modulated carriers.
For more on alignment, see "Mystified by Return Path Alignment? Get Your Upstream Fiber Links Aligned" in the March 2000 issue of CT.
OK, now that the network has been properly aligned, whats next?
Managing ingress and other gremlins
Look at the upstream spectrum in the headend, and see just how good or bad the ingress is.
If the spectrum is relatively clean, and your network meets or exceeds the minimum recommended downstream and upstream parameters outlined in the Data Over Cable Service Interface Specification (DOCSIS) RF Interface Specification (this is on-line at www.cablemodem.com/SP_RFI_I05_991105.pdf), you deserve a tip of the ol hat.
If your reverse spectrum looks like most, youll need to tighten up your downstream leakage.
"But the plant meets the Federal Communications Commissions 20 microvolt per meter (µV/m) leakage limit," you argue, "and our most recent cumulative leakage index was in the low 60s."
Thats probably not good enough.
Most operators who have upstream ingress under control keep downstream leakage well below the FCCs 20 µV/m limit-often as low as 5 µV/m or less. These same operators have annual flyovers in the 99th percentile, or cumulative leakage index numbers far below 64.
Jim Kuhns, director of field support for Terayon Communication Systems and SCTE chairman of the board and Region 7 director, is a frequent return-path speaker at industry seminars. He told me that he is constantly approached by seminar attendees looking for the upstream ingress silver bullet. "We came to learn about two-way, and half of your presentation was on downstream leakage," they complain.
If your system has leakage, it has ingress. Where cable signals leak out, over-the-air signals will leak in. Youve got to have a tight plant if you want reliable two-way. "Its not rocket science," says Kuhns. Getting ingress under control is largely "low-tech stuff," he adds.
The real issue is whether or not youre willing to devote the necessary resourcestime and manpowerto tighten up the plant. Fix your leakage, and the worst of your ingress will go away.
Once you get over the alignment and ingress hurdles, youll be able to tackle things like CPD. Common path distortion can be masked by excessive ingress or noise, and may be made worse by improper downstream alignment. If you dont have CPD or its low enough to not be a problem, consider yourself fortunate. Otherwise, get a couple bottles of aspirincommon path distortion can be a real headache.
But it doesnt stop here. Keeping the network properly aligned, leakage and ingress down to a dull roar and other reverse path gremlins at bay all are on-going battles. "It just takes a lot of TLC," Kuhns says.
Ron Hranac is a consulting systems engineer for Cisco Systems, and senior technology editor for CT. You may reach him at .
Back to April 2001 Issue

Access Intelligence's CABLE GROUP
Communications Technology | CableFAX Daily | CableFAX's CableWORLD | CT's Pipeline
CableFAX Magazine | CableFAX databriefs | Broadband Leaders Retreat | CableFAX Leaders Retreat
|